>3.33 mV/V output signal.
>Pressure ranges from 0-35 to 0-2000 bar / 0-500 to 0-30000 psi
> Fluid-filled system for temperature stability
> Accuracy: <±0.25% FSO (H); <±0.5% FSO (M)

The main characteristic of this series is the capability to read temperature of the media up to 400°C.
The constructive principle is based on the hydraulic transmission of the pressure. The fluid-filled system assures the temperature stability.

The physical measure is transformed in an electrical measure by means the strain-gauge technology.
Description

Pressure ranges from: 0-500 to 0-30000 psi / 0-35 to 0-2000 bar
Strain gage Wheatstone bridge
Accuracy: <±0.5% FSO (M) <±0.25% FSO (H);
Fluid-filled system for temperature stability
Grade of protection: IP65 (6-pin connector version)
Standard diaphragm is 15-5 PH stainless steel with GTP coating
Internally generated 80% calibration signal (R-Cal)
1/2-20 UNF, M18x1.5 standard threads; other types available on request
Fully interchangeable with all existing brands
17-7 PH corrugated diaphragm with GTP coating for ranges below 100 bar-1500 psi
Other diaphragms available on request